 FA-100 F.A.S. Series :

 Number of readers : 6881
 
 
Conventional :
 
FA-100 Series
(1, 2 & 5 Zones)
 
Fire Alarm Control Panels
  
 

Features

- One, Two & Five Style ‘B’ initiating circuit
- Two Style ‘Y’ indicating circuit (1.25 Amps)
- Individual Zone Silence/Disconnect switches
- Powerful 3 mA capacity per zone for 2-wire smoke detectors
- Common alarm Relay contact
- Selectable ‘N.O’ or ‘N.C’ common trouble contact
- Power ON LED (Green)
- Zone Alarm LED (Amber)
- Signal Trouble LED (Amber)
- Ground Fault LED (Amber)
- Battery Fault LED (Amber)
- Alarm Silenced LED (Amber)
- Common Trouble LED & Silence switch
- Remote Trouble Indicator output
- Remote Power On output
- Selectable 1 minute Signal silence inhibit
- Extensive Transient Protection on all circuits
- Red exterior colour
- Annunciator Outputs available
- UL, SCFM & MEA Approved
 
 
 
FA-101U
ONE ZONE FIRE ALARM CONTROL PANEL
 
Description :

     The Mircom FA-101U panel is designed for non-coded fire alarm systems in small commercial, institutional and industrial occupancies. A slim-line design and a neutral beige exterior colour offers an unobtrusive appearance to complement any interior.

The FA-101U includes one circuit board providing all the essentials for a complete fire alarm system. One Style ‘B’ initiating circuit and one Style ‘Y’ indicating circuit are provided by the FA-101U. The indicating circuit is protected from shorts by self-restoring circuitry.

Supervision includes ground fault detection, battery low level or open wire fault, initiating and indicating circuit wiring faults and loss of A.C. power. Initiating circuits are supervised for opens and power. Indicating circuits are supervised for opens and ground faults. Indicating circuits are supervised for opens, shorts and ground faults. LED indicators are provided for Zone Alarm, Zone Trouble, A.C. On, Battery Fault, Ground Fault, Common Trouble, Signal Trouble and Silence Silenced. Switches are provided for Zone disconnect/silence, trouble silence and reset.
 
Conventional :
 
FA-102U
TWO ZONE FIRE ALARM CONTROL PANEL 
 
Description :
 
     The Mircom FA-102U panel is designed for non-coded fire alarm systems in small commercial, institutional and industrial occupancies. A slim-line design and a neutral beige exterior colour offers an unobtrusive appearance to complement any interior.

The FA-102UA includes one circuit board providing all the essentials for a complete fire alarm system. Two Class ‘B’ initiating circuit and one Style ‘Y’ indicating circuit are provided by the FA-102A. The indicating circuit is protected from shorts by self-restoring circuitry.

Supervision includes ground fault detection, battery low level or open wire fault, initiating and indicating circuit wiring faults and loss of A.C. power. Initiating circuits are supervised for opens and power. Indicating circuits are supervised for opens and ground faults. Indicating circuits are supervised for opens, shorts and ground faults. LED indicators are provided for Zone Alarm, Zone Trouble, A.C. On, Battery Fault, Ground Fault, Common Trouble, Signal Trouble and Silence Silenced. Switches are provided for Zone disconnect/silence, trouble silence and reset.

 

 
Conventional :
 
FA-1025U
FIVE ZONE FIRE ALARM CONTROL PANEL

 

 
Description :
 
     The Mircom FA-1025U panel is designed for non-coded fire alarm systems in small commercial, institutional and industrial occupancies. A slim-line design and a neutral beige exterior colour offers an unobtrusive appearance to complement any interior.

The FA-1025U includes one circuit board providing all the essentials for a complete fire alarm system. Five Style ‘B’ initiating circuit and two Style ‘Y’ indicating circuits are provided by the FA-1025A. The indicating circuit is protected from shorts by self-restoring circuitry.

Supervision includes ground fault detection, battery low level or open wire fault, initiating and indicating circuit wiring faults and loss of A.C. power. Initiating circuits are supervised for opens and power. Indicating circuits are supervised for opens and ground faults. Indicating circuits are supervised for opens, shorts and ground faults. LED indicators are provided for Zone Alarm, Zone Trouble, A.C. On, Battery Fault, Ground Fault, Common Trouble, Signal Trouble and Silence Silenced. Switches are provided for Zone disconnect/silence, trouble silence and reset.

 
     Upon a trouble condition, the trouble LED will flash and the trouble audible signal will pulse. Activating the “Trouble Silence” switch silences the trouble signal and the “Trouble“ LED remains flashing.

When the trouble condition clears, the common trouble LED restores to normal and the common trouble buzzer resounds steady until the Trouble signal silence switch is returned to normal. The alarm signals cannot be silenced for one minute if the one minute inhibit feature has been selected (cut jumper).

The common alarm relay can follow the signal circuit or lock on until the Alarm has been reset. This option is jumper selectable.

Annunciation outputs are provided for alarm, remote trouble indicator and buzzer. Lamp supervision is jumper selectable.

The FA-1025A controls are behind a durable locked door. The cabinet will accommodate a 4 or 7 AH battery pack.
 