 FA-200 F.A.S. Series :

 Number of readers : 8789
 
 
Conventional:
 
CPU Based FA-200 Series
(4 & 8 Zones)
 

FA-204E

FIRE ALARM CONTROL PANEL

 

Description :

 

     Mircom’s FA-204E Fire Alarm Control Panel is a microprocessor based unit designed for small to medium commercial, institutional and industrial occupancies. Fully configurable using DIP switches, it enables the user to configure the system to meet their specific requirements.

The FA-204E comes standard with 4 Class B (Style B) Initiating Circuits which may be configured as 2 Class A (Style D) circuits. In addition it comes equipped with 2 Class A/B (Style Z/Y) Indicating circuits which are each rated at 1.7 amps. The FA204E can be expanded up to 8 Class B (Style B) or 4 Class A (Style D) Initiating Circuits and 4 Class A/B (Style Z/Y) Indicating circuits with the addition of a DM-204 Adder Circuit Module. The panel also includes a 5 Amp Power Supply which powers the system and supplies a 4-wire resettable regulated smoke power supply of 24 VDC 100mA maximum.

The FA-204E utilizes a simple DIP switch configuration for programming initiating and indicating circuits as well as the enabling and disabling of system functions such as Signal Silence, Fire Drill and Auxiliary Disconnect. The FA-204E allows for initiating circuits #3 and #7 to be optionally configured for Waterflow and initiating circuits #4 and #8 to be configured for Latching/Non-Latching Supervisory. In addition the FA-204E allows for Alarm Verification on the Initiating circuits. The Indicating circuits may be configured as Silenceable or Non-Silenceable with the audibles configured for Steady, March-Time, Temporal Code, or California Code.
 
 
 

 

Features

- 4 Class B (Style B) Initiating Circuits which may be configured as 2 Class A (Style D) circuits. Expandable up to 8 Class B (Style B) or 4 Class A (Style D) Initiating Circuits

- 2 Class A/B (Style Z/Y) Indicating Circuits with individual trouble indicators (1.7 Amps max. per circuit.) Expandable up to 4 Class A/B (Style Z/Y) Indicating circuits

- Each Indicating Circuit can be configured as Silenceable or Non-Silenceable. Audibles may be configured as Steady, Temporal Code, California Code or March Time

- Primary Input Power: 120 volts, 60 Hz, 4 Amps maximum Indicating Current: 24VDC unfiltered, 5 Amps maximum Standby Power: 24VDC Standby Batteries
- It comes with a durable CAT-30 lock and key. Space is provided for up to 10 AH batteries.

- Initiating Circuits #3 and #7 can be configured for Waterflow while Initiating Circuits #4 and #8 can be configured for Latching/Non-Latching Supervisory

- Auxiliary relay contacts for Common Alarm, Common Trouble and Common Supervisory. If no Supervisory circuits are enabled, the Supervisory relay becomes a second Alarm relay.

- Zone Disconnect Switches

- Built-in RS-485 Interface for RAM-208 Multiplexed Remote Annunciators (Up to 3 Annunciators)

- Interface for Remote Trouble Indicator

- Built-in Walk Test operation

- Auto Signal Silence

- Selectable Alarm Verification on Initiating Circuits

- 5 Amp Power Supply

- Output for 4-wire resettable regulated smoke power supply of 24 VDC 100mA maximum

- Output for RTI or Remote Annunciators of 24VDC, 300 mA max, unfiltered

- Extensive Transient Protection

- Easy configuration via DIP switches

 

Optional Modules :

- DACT-100A Digital Communicator
- PR-300 Polarity Reversal and City Tie Module
- DM-204 Four Zone Adder Module
- RM-204 Quad Relay Module
- RM-208 Eight Relay Module

 

 

FA-200 SERIES ACCESSORIES :

    The FA-200 Series Microprocessor Based Fire Alarm System can be configured to meet virtually any requirement.  To facilitate this flexibility, the panel has a number of add-on modules which allow the system to perform certain functions.

 

DM-204
Four Initiating Circuit & Two Indicating Circuit Module
     The DM-204 Module provides the FA-204E Fire Alarm Control Panel with up to 4 Class B (Style B) or 2 Class A (Style D) Initiating Circuits. In addition it provides up to 2 Class A/B (Style Z/Y) Indicating Circuits which are rated for 1.7 Amps each. Each of the indicating circuits can be configured for silenceable or non silenceable. In addition each circuit comes with an individual trouble indicator. All circuits are power limited for use with limited energy cable. The DM-204 consists of a PC board which mounts at the bottom of the chassis. The PC board is connected via cables to the board on the main chassis.
 
RM-204
Auxiliary Quad Relay Module
 
     The RM-204 Auxiliary Relay Module provides the FA-200 Series with four configurable auxiliary relays. The relays can be configured for either relay per zone, Common Alarm relay(s) or Common Supervisory relay(s). Each relay is rated for 28 VDC @ 1 Amp max.
 
RM-208
 
Eight Relay Module
 
 
 
 
     The RM-208 Auxiliar y Relay Module provides the FA-200 Series with eight configurable auxiliary relays. The relays can be configured for either relay per zone, Common Alarm relay(s) or Common Supervisory relay(s). Each relay is rated for 28 VDC @ 1 Amp max.
 
 
PR-300
Polarity Reversal & City Tie Module
     The PR-300 Polarity Reversal & City Tie Module allows connection to two different types of monitoring systems. The City Tie provides an output of 24 VDC at 210 mA max. The module supervises the City Tie connection and will provide a system trouble if not connected. A terminating resistors supplied with the module. The Polarity Reversal provides a 24 VDC output for normal condition and a polarity reverse 24 VDC output for alarm. The module is also capable of transmitting a system trouble “Zero Volts.” This option is jumper selectable. The output current is limited to 8 mA.
 
DACT-100A
Digital Alarm Communicator Transmitter/Dialer Module
 
     The DACT-100A Digital Alarm Communicator Transmitter/Dialer Module allows the FA-200 Series Fire Alarm Control Panels to use one or two phone lines to call a Central Station and report a local Alarm, Trouble or Supervisory condition. Requiring two supervised telephone lines, the DACT-100A can be programmed to use the Security Industry Association (SIA) Digital Co mmunication Standard (DCS) and Ademco Contact ID protocols.
The DACT-100A is powered by the FA-200 Series Fire Alarm Control Panels and communicates with them via contact closure inputs. The CFG-100 Configuration Tool is required to program the DACT-100A.
 
 
 