 FX-2000 Panels :

 Number of readers : 12449
 
Addressable:

FX-2000 SERIES

ANALOGUE INTELLIGENT FIRE ALARM CONTROL PANEL
 

 
 
MEA      
 
 
 
Description :

     Mircom’s FX-2000 Series Intelligent Analog Fire Alarm Control Panel is designed to provide maximum flexibility of analog system requirements while also providing easy installation and operation at a cost-effective price.

     The FX-2000 Base Panel consists of one Intelligent Analog Loop Controller capable of supporting 99 Analog Sensors and 99 Addressable Modules which can be wired in Class A (Style 6 or 7) or Class B (Style 4). The system can be expanded by adding additional Analog Loop Controller Modules. In addition the base panel supports 16 conventional hardwire adder modules such as the DM-1008A Initiating Circuit Module, SGM1004A Indicating Circuit Module and the RM-1008A Relay Circuit Module. Additional conventional hardwire adder modules can be added with the ALC-H16 Adder Hardwire Loop Controller Module, which allows the system to support an additional 16 conventional adder modules. The base panel also consists of 4 Class A/B (Style Z/Y) Indicating Circuits rated at 1.7 Amps each and either a 6 or 12 Amp Power Supply. Equipped with a large 4 x 20 Back-lit Alphanumeric LCD display, the FX-2000 utilizes a simple Menu system complete with a directional keypad, common control switches and LEDs, Alarm Queue switches and LEDs, two configurable input switches and 16 configurable zone LEDs.

 

Features :

- Large system capacity

- Modular design

- 99 Analog Sensors and 99 Addressable Modules

- Each Analog Loop can be wired in Class A  or B

- Base system supports 16 Conventional Hardwired Modules

- 6 or 12 Amp power supply

- Four Class A/B Indicating Circuits rated at 1.7 Amps each

- Configurable for Two Stage operation

- Three level password protection

- Panel Security to Protect Site Configurations

- Password protection for all front panel function switches

- Switch Inputs which allows for Multifunctional outputs

- 4 Alarm Queues, LEDs for Alarm, Supervisory, Monitor, Trouble

- Common Alarm, Common Supervisory and Common Trouble

- RS-232 output for remote system printer or CRT

- 1000 Alarm History Log for alarm and 2000 Event - for all events

- Front Panel Auto-Configure and/or
- Computer laptop Programmable

- Large 4 by 20 character Back-lit LCD Display

- Common Control switches and/or
- Indicating LEDs for
  - System Reset,
  - Signal Silence,
  - Fire Drill,
  - Acknowledge,
  - General Alarm,
  - Lamp Test,
  - A.C. On,
  - Pre-Alarm and
  - Ground Fault

- Built-in One Man Walk Test operation

- Configurable for Coded Operation

- 16 Zone configurable LED annunciator

- Supports an RS-485 interface to the QX-5000 V.E. System

- Panel Selection for for smoke sensors (sensitivity) via computer

- Automatic Drift Compensation

- Capability to adjust Intelligent Smoke Detector sensitivity level

 
 
 
     The FX-2000 is field programmable via the front panel auto configuration or a laptop computer. In addition, it allows for a three level password protection that can be field defined via a laptop computer. This unique feature allows the installer to determine what functions are accessible for each password level.

The system is also equipped with two Event History Logs; one for Alarm and the other for full panel sequence events. The Alarm History Log (1000 events) contains all alarm related functions while the Event Log (2000 events) provides a full sequence log of all operations, as well as alarms and troubles. Both Event History Logs can be used during the One Man Walk Test operation. This allows the event logs to be downloaded to a laptop or printer for a permanent record.

The FX-2000 is a very flexible system which supports both internal and external annunciation modules. The internal annunciation modules consist of the RAX-1048 Programmable Zone LED Annunciator, the IPS-2424 Programmable Input Switches Module, the FDX-008 Fan Damper Module and the AGD-048 Adder Graphic Driver Module.

 

All Input Circuits Can be Configured for :

  • Non-verified Alarm

  • Verified Alarm
  • Waterflow
  • Latching Supervisory
  • Non-latching Supervisory
  • Monitor
  • Trouble Only
  • Remote Switch Inputs
 
 
 
     All of the input configuration types listed above, with the exception of remote switch can be programmed to operate relays, signal and strobe circuits for hardwired or addressable devices. Please refer to the chart below for correlations. The input circuits configured as non-latching will cause the output circuits configured to them to follow the state of the input device. This feature allows for the connection of multiple panels together for signal operation.

     All of these modules mount within the panel and are driven from the main LCD display. The external annunciator modules include the RAM-1032 and RAX-1048 LED Remote Annunciators, the MGD-32 Master Graphic Driver Module, the MGDS-16/16 Master Graphic Driver Module and the RAX-LCD Remote LCD Shared Display. The RAX-LCD Remote LCD Shared Display provides the same features as the main display on the FX-2000. In addition the RAX-LCD also acts as a driver module that allows for the RAX-1048, IPS-2424, FDX-008 andAGD-048 to be connected to it. The RAX-LCD is required as a driver module any time any of the above mentioned external annunciator modules are programmed differently from those on the main panel or are mounted remote from the main panel.

     In addition to these adder modules, the FX-2000 also supports the UDACT-100A Digital Communicator Module and the PR-300 Polarity Reversal/City Tie Module. The FX-2000 also supports an RS-485 interface to the QX-5000 Emergency Zoned Audio System.

     The Remote Switch input, which must be momentary, allows any input type device (addressable or hardwired) to be configured as a common control functions such as fire drill, system reset, signal silence etc. The remote switches operate in a momentary mode like the control switches on the FX2000 main panel. For functions such as fire drill, the remote switch functions in a toggle mode, with one press for “on” and one press for “off”. The remote switch is supervised for “stuck in on” positions, where the switch input is activated (stuck) for more than 30 seconds. If this occurs, a trouble is generated and clears when the input goes away.

 

 

FX-2000 Standard Series

 

FX-2000 Standard Series System Maximums :

  • 150 Output Circuits
  • 5 Intelligent Addressable Loops
  • 4 Remote LCD Annunciators
  • 4 Main LED Annunciators
  • 100 Manual Control Switches

 

1). FX-2003-6/12 Compact Main Chassis :

     The FX-2003-6/12 Compact Main Chassis comes complete with one Analog Loop Controller (99 Analog Sensors and 99Addressable Modules), 4 Class A/B (Style Z/Y) Indicating Circuits (1.7 Amps each), a 4 line by 20 character back-lit LCD display, 16 Zone LED Annunciator and either a 6 Amp Power Supply which charges 10-24 AH batteries or a 12Amp Power Supply which charges 17-40AH batteries. The FX-2003-6/FX2003-12 supports 16 conventional adder modules and provides space for 3 adder modules. The FX-20036/FX-2003-12 mounts in the BBX-1024 enclosure.

 

2). FX-2017-12A Mid-Size Main Chassis :

     The FX-2017-12A Mid-Size Main Chassis comes complete with one Analog Loop Controller (99 Analog Sensors and 99 Addressable Modules), 4 Class A/B (Style Z/Y) Indicating Circuits (1.7 Amps each), a 4 line by 20 character back-lit LCD display, 16 Zone LED Annunciator and a 12 Amp Power Supply which charges 17-40 AH batteries. The FX-201712A supports 16 conventional adder modules and has space for up to 17 adder modules and 3 internal annunciator adder modules. The FX-2017-12Amounts in the BBX-1072A enclosure.

 

3). FX-2009-12 Large Size Main Chassis :

     The FX-2009-12 Large Size Main Chassis comes complete with one Analog Loop Controller (99 Analog Sensors and 99 Addressable Modules), 4 Class A/B (Style Z/Y) Indicating Circuits (1.7 Amps each), a 4 line by 20 character back-lit LCD display, 16 Zone LED Annunciator and a 12 Amp Power Supply which charges 17-40 AH batteries. The FX-2009-12 supports 16 conventional adder modules and provides space for up to 9 adder modules and 2 internal annunciator adder modules. The FX-2009-12 mounts in the BB5000 Series enclosures.

 

4). ECX-0012 Expander Chassis

     The ECX-0012 Expander Chassis for the FX-2009-12/ FX-2009S-12 supports up to 12 adder modules and has space for 2 internal annunciator modules. The ECX0012 mounts in the BB-5000 series enclosures.

 

 

FX-2000 Enhanced Series

 

    Mircom’s FX-2000 Enhanced Series feature a powerful system capacities. The Main Chassis are available CPU which increases the processing of inputs/outputs in the same configurations as the standard FX-2000 to provide faster response times and allow for larger Series.

FX-2000 Enhanced Series System Maximums:

  • 1500 Input Circuits

  • 300 Output Circuits
  • 30 Intelligent Addressable Loops
  • 24 Remote LCD Annunciators
  • 4 Main LED Annunciators
  • 300 Manual Control Switches

 

1). FX-2003S-12 Enhanced Series Compact Main Chassis :

     The FX-2003S-12 Enhanced Compact Main Chassis comes complete with 4 Class A/B (Style Z/Y) Indicating Circuits (1.7 Amps each), a 4 line by 20 character backlit LCD display, 16 Zone LED Annunciator and a 12 Amp Power Supply which charges 17-40 AH batteries. The FX-2003S-12 provides space for 3ALC-396S Dual Loop Controller Modules. The FX-2003S-12 mounts in the BBX-1024 enclosure.

 

2). FX-2017S-12A Enhanced Series Mid-Size Main Chassis :

     The FX-2017S-12A Mid-Size Main Chassis comes complete with 4 Class A/B (Style Z/Y) Indicating Circuits (1.7 Amps each), a 4 line by 20 character back-lit LCD display, 16 Zone LED Annunciator and a 12 Amp Power Supply which charges 17-40 AH batteries. The FX-2017S-12A provides space for up to 17 adder modules/Dual Loop Controllers and 3 internal annunciator adder modules. The FX-2017S12A mounts in the BBX-1072A enclosure.

 

3). FX-2009S-12 Enhanced Series Large Size Main Chassis :

      The FX-2009S-12 Enhanced Large Size Main Chassis comes complete with 4 Class A/B (Style Z/Y) Indicating Circuits (1.7 Amps each), a 4 line by 20 character back-lit LCD display, 16 Zone LED Annunciator and a 12 Amp Power Supply which charges 17-40 AH batteries. The FX-2009S-12 electrically supports 16 conventional adder modules and provides space for up to 9 adder modules and 2 internal annunciator adder modules. The FA-2009S-12 mounts in the BB-5000 Series enclosures.

 

4). ECX-0012 Expander Chassis :

     The ECX-0012 Expander Chassis for the FX-2009-12/ FX-2009S-12 supports up to 12 adder modules and has space for 2 internal annunciator modules. The ECX0012 mounts in the BB-5000 series enclosures.

 

 

Adder Loop Controller Modules

 

ALC-198S

Single Analog Loop Controller Module

     The ALC-198S Single Analog Loop Controller Module provides an additional analog loop to the FX-2000 consisting of 99 Analog Sensors and 99 Addressable Modules. The ALC-198S occupies one module slot in the FX-2000 main or expander chassis.

 

ALC-396S

Dual Analog  Loop Controller Module

     The ALC-396S Dual Analog Loop Controller Module provides Two /2/ additional analog loops to the FX-2000 consisting of 99 Analog Sensors and 99 Addressable Modules per loop. The ALC-396S occupies one module slot in the FX-2000 main or expander chassis.

 

ALC-H16

Hardwire Loop Controller Module

     The ALC-H16 Hardwire Loop Controller Module allows the FX-2000 to support an additional sixteen (16) conventional hardwire adder modules. The hardwire modules consist of the DM-1008 Eight Initiating Circuit Module, SGM-1004 Four Indicating Circuit Module and the RM-1008 Eight Relay Circuit Module. The ALCH16 occupies one module slot in the FX-2000 main or expander chassis.

 

 

Adder Auxiliary Modules

 

DM-1008A

Eight Initiating Circuit Module

     The DM-1008A provides 8 Class B (Style B) or 4 Class A (Style D) Initiating Circuits configurable for Alarm, Supervisory or Trouble zones. TheDM-1008A occupies one module slot in the FX-2000 main or expander chassis.

 

SGM-1004A

Four Indicating Circuit Module

    The SGM-1004A provides 4 Class A/B (Style Z/Y) Indicating Circuits configurable as Silenceable or Non-Silenceable. Each Indicating Circuits is rated at 1.7 Amps. Each of the indicating circuits have individual signal silence inputs which are jumper selectable. The SGM-1004A occupies one module slot in the FX-2000 main or expander chassis.

 

RM-1008A

Eight Relay Circuit Module

     The RM-1008A provides the FX-2000 with 8 individual configurable relays per module. Each relay provides one Form C contact rated at 28 VDC @1 Amp (resistive load). The RM-1008A occupies one module slot in the FX-2000 main or expander chassis.

 

UDACT-100A

Digital Alarm Communicator Module

 

PR-300

Polarity Reversal/City Tie Module

 

     The UDACT-100A Digital Alarm Communicator Module. The PR-300 Polarity Reversal/City Tie Module provides allows the FX-2000 to transmit addressable point the system with a supervised City Tie (24 VDC/200 mA information to a central station. Hardwired points will max.) and Polarity Reversal connection (24 VDC (open also be transmitted as zones to the central station. circuit), 8 mA max. (shorted)). The PR-300 mounts in The UDACT-100A uses the Ademco Contact ID and the FX-2000 main chassis. SIA-DCS protocols. The UDACT-100A occupies one module slot in the FX-2000 main or expander chassis.

 

 

Programmable Modules

 

RAX-1048

Programmable Zone LED Annunciator Module

     The RAX-1048 Programmable Zone LED Annunciator Module provides 48 programmable bi-coloured LEDs. The RAX-1048 connects to the main panel or the RAX-LCD Shared Display when mounted remotely. The RAX-1048 occupies one display position in the BB-1000 or BB-5000 enclosures.

 

RAX-2096

Programmable Zone LED Annunciator Module

     The RAX-20968 Programmable Zone LED Annunciator Module provides 96 programmable bi-coloured LEDs. The RAX-2096 connects to the main panel or the RAX-LCD Shared Display when mounted remotely. The RAX-2096 occupies one display position in the BB-1000 or BB-5000 enclosures.

 

IPS-2424

Programmable Input Switches Module

     The IPS-2424 Programmable Input Switches Module provides 24 programmable switches that can be configured for ancillary functions such as zone bypass or added common control functions. The switches operate in a toggle operation with one press for “on” and one press for “off”. The IPS-2424 connects to main panel or the RAX-LCD when mounted remotely. The IPS-2424 occupies one display position in the BB-1000 or BB-5000 enclosures.

 

FDX-024

Fan Damper Module

     The FDX-024 Fan Damper Module provides 24 individually programmable switches which can be used for fan or damper control. Each circuit has 24 Bi-Coloured LEDs (Green/Amber) and 24 Amber Select LEDs. The FDX-024 connects to main panel or the RAX-LCD when mounted remotely. The FDX024 occupies one display position in the BB-1000 or BB-5000 enclosures.

 

FDX-008

Fan Damper Module

     The FDX-008 Fan Damper Module provides individually programmed circuits which can be used for fan or damper control. Each circuit has a slide-in label, a three position selector switch, green “run or open” LED and an amber “off or closed” LED. The three-position selector switch has a centre “auto” position, a left “off or close” position and a right “on or open” position. The FDX-008 connects to the main panel or the RAX LCD when mounted remotely. It uses MIX-M500CH for control of fans or dampers and two MIX-M501A for status. The FDX-008 occupies one display position in the BB-1000 or BB-5000 enclosures.

 
 
 