WELCOME  to  ...       EIN-AZAITOON  Company  For  Advanced Systems Int.

     MAIN SYSTEMS:
      SECURITY SYSTEMS
      FIRE ALARM SYSTEMS
      SURVEILLANCE SYSTEMS
      AUTOMATION SYSTEMS
     + SMATV SYSTEMS
      PARTNERS
     - PRICES (Login)
     - CONTACT US
     - ABOUT US
     - FEEDBACK

 F.A. Pull Stations :

 Number of readers : 8229
 
Conventional:

MS-400 SERIES

EMERGENCY MANUAL FIRE ALARM PULL STATION
 
 
  Approved
 

MS-401U : Single Manual Pull Station

Description

     Attractive and durable, Mircom’s MS-400U Series of pull stations provide manual fire reporting. The MS400U Series pull stations are non-coded, single or double action devices which initiate an alarm when pulled. Resetting is accomplished by inserting a 3.25mm screwdriver from the front. The handle, once pulled will remain open and cannot be reset without utilizing the screwdriver.  The MS-400U Series pull stations are constructed of durable aluminum and finished in red. An abrasion resistant label with large, raised letters provides clear legible instructions.

The model MS-402U (two stage) is similar to the MS401U (single stage) except it contains an additional General Alarm (G.A.) N.O. switch. For safety reasons, the G.A. switch is only accessible after the handle has been pulled. A special key is supplied with each unit.

The model MS-405U is similar to the MS-401U except it has an additional N.O. switch. The model MS-406U is similar to the MS-402U except it has an additional N.O. switch. The model MS-407U is similar to the MS-401U except it has an additional N.C. switch. The model MS-408U is similar to the MS-402U except it has an additional N.C. switch. All pull stations can be easily converted from single action to double action station by the addition of the MS-DA double action lever.

 

Features

  • Durable Extruded Aluminum Construction
  • Attractive, Low Profile Design
  • Standard Single Gang Mount
  • Converts to Double Action
  • Glass Rod Optional (one provided)
  • Ingress Protection IP64

 

Operation

     Pulling on the station’s handle will release the internal switch to trigger the alarm detection circuit. The MS-402U, MS-406U and MS-408U (two stage versions) also provide a key switch which is accessible after the handle has been pulled. Operation of the key switch, when connected to a separate general alarm circuit, will initiate the 2nd stage of a two stage alarm signaling system.

 

Specifications

     The single action pull station shall be Mircom’s MS-400U Series. Operating instructions shall be in raised English lettering and the unit shall be constructed of extruded aluminum, finished in red enamel paint to provide quick identification. Pulling the handle shall initiate immediate operation of the alarm detection circuit. In addition, those stations installed in a two stage system shall come equipped with an internal key switch designed to operate the 2nd stage alarm initiating circuit. All manual fire alarm stations shall be installed as per the specific requirements outlined in the UL codes, as well as all other applicable national or local codes.




MS-500 SERIES

EMERGENCY MANUAL FIRE ALARM PULL STATION
 
 
  Approved
 

MS-501U : Single Manual Pull Station

Description

     Same Features as MS-400 Series, all MS-500 Series Pull Stations come equipped with the universal CAT-30 Key. Attractive and durable, Mircom’s MS-500 Series Pull Stations provide manual fire reporting. The MS-500 Series Pull Stations are non-coded, single or double action devices which initiate an alarm when pulled.

The MS-502 (two stage) is similar to the MS-501 (single stage) except for an additional General Alarm (G.A.) N.O. switch. For safety reasons, the G.A. switch is only accessible after the handle has been pulled. A special key is supplied with each unit. All pull stations can be easily converted from a single action to double action by the addition of the MS-DA double action lever.




MS-600XPU SERIES

EXPLOSION-PROOF MANUAL PULL STATIONS
 
 
  Approved
 
 

MS-610XPU : Dual Manual Pull Station

Description

    The MS-600XPU Series is a high-quality, die-cast metal, explosion-proof manual fire alarm pull station available in either single or dual action configurations. It is UL Listed and Factory Mutual Approved for use in Class I, Groups B, C, and D; Class II, Groups E, F, and G; and Class III hazardous environments.

The MS-600XPU Series has a marine rating and is approved for NEMA-4X applications. The MS600XPU Series has a DPDT switch with terminal strip connections. All models in the series have been tested for compliance to the latest requirements of the Americans with Disabilities Act (ADA) and comply with the Standards for front wheelchair access when installed at less than 48 inches above the finished floor and for side-wheelchair access when installed at less than 54 inches above the finished floor.

 

Features

  • Single or Dual Action
  • Key lock reset
  • Screw Terminal connections
  • High-gloss red enamel finish
  • Double pole double throw switch
  • Marine and Nema 4X rated
  • IP67
  • ADA compliant

 

Operation

     The MS-601XPU single action station is operated simply by pulling the Pull handle on the front of the station as far down as it will go, at which point the handle locks into place and is easily visible from up to 16m. The MS-610XPU dual action model features a Push bar that rotates inward, allowing the Pull handle to be grasped in a one-handed motion. The activated station is reset by opening the station with a key, placing the handle in the normal, upright position, and re-locking the station.

 

Architect and Engineer Specifications

     The manual pull station shall be UL listed and FM approved for Explosion-Proof, Marine and NEMA 4X applications for use in the intended environment. It shall be painted red with raised white identification lettering. The station shall have two sets of form C contacts. It shall be a non-coded, single action or dual action station that shall latch in the activated position. When activated, the latched handle shall be easily recognizable as being in the activated position when viewed from a distance of at least fifty feet. A locking mechanism shall be provided to prohibit unauthorized reset of the manual station. A key shall be required to unlock and reset the station.

 

Specifications
Switch Rating: 1 amp at 30 VDC
10 amps at 120 VAC
Switch Type: DPDT
Terminal Size: Up to 14 AWG
Temperature: -55°C to +150°C
Humidity: 90% Relative Humidity at 100°F
Explosion Hazard Classifications: Class I Groups B, C, and D
Class II Groups E, F, and G
Class III
Weatherproof Classifications : NEMA Type 4X
Other Classifications : UL Marine Listing
Pull Station Dimensions: 6 5/16” H x 3 1/4” W x 3 7/8”D
Conduit Fittings: 2
Conduit Fitting Size: 3/4” - 14 NPT
Color: Face Plate - Red with raised white letters




MS-700U SERIES

 
EMERGENCY MANUAL FIRE ALARM PULL STATION
 
 
  Approved
 
 

                                         MS-701U                                  MS-702U

                             Single Action Pull Station           Dual Action Pull Station

 

Description

      Mircom’s MS-700U Series Manual Pull Stations provide manual fire reporting. These high quality, die-cast metal  pull stations are available in either single or dual action  configurations with SPST contacts and terminal strip connections. The normally open contact, which closes  when the pull station is activated, is rated for 1 amp,  30 VDC. The contacts are gold plated to avoid the risk of corrosion.  The MS-700U Series Pull Stations are available in many different configurations as either single or dual-action devices.

      The MS-701U is a single action, single stage pull  station. Model MS-710U is a single stage, dual action pull station.  All models are available with key resets, terminal connectors, SPST gold contacts and CAT-30 lock  and keys. The units mount on a standard single gang  backbox, Mircom’s BB-700 surface metal backbox or  BB-700WP weather proof backbox.

Features

  • Single or Dual Action
  • Key resettable
  • Terminal connectors
  • Gold plated SPST contacts
  • Optional auxiliary contacts
  • High-gloss red enamel finish
  • Plastic breakrod
  • Ingress Protection IP64
  • Mounts on standard single gang box, Mircom’s BB-700 surface metal backbox or BB-700WP weather proof backbox

    Operation

          The MS-701U SingleAction Pull Station is operated by pulling down the handle marked “PULL HANDLE” on the front of the station. The MS-710U Dual Action Pull  Station is operated by pushing the bar labelled “PUSH BAR” and then pulling down the handle marked “PULL  HANDLE”. The MS-700U Series Pull Stations are reset by opening the station with the key, placing the handle in the normal upright position and re-locking the station.

    Specifications

          The manual pull station shall be Mircom’s MS-700U Series. Operating instructions shall be in raised English lettering and the unit shall be constructed of  high quality die-cast metal and finished in red enamel paint to provide quick identification. Pulling the handle shall initiate immediate operation of the alarm detection circuit.  All manual fire alarm stations shall be installed as per the specific requirements outlined in the UL  codes, as well as all other applicable national or local  codes.  Final acceptance is subject to the local authority having jurisdiction.

    Dimensions: H: 125mm x W: 89mm x D: 51mm

    Switch Rating: 1 Amp @ 30 VDC, 0.1 Amp @ 125 VAC

    Current Consumption: Standby: 400 uA Alarm: 5.5 mA

    Color: Red with raised white letters, white pull bar with raised black letters.
     
     
     
     
    Ein-Azaitoon Co. - ASI
     
     

    F.A. Pull Stations

    Number of readers : 8229